Palm's Instruments Division

Electroless Nickel Controllers:
  Ni240 2200 1101



Model 2200 Electroless Nickel Controller

The Model 2200 is a state-of-the-art, automatic controller for electroless nickel plating baths. It will maintain the bath's strength. within very close limits with a minimum of operator assistance. The controller is very easy to use and may be adapted for most electroless nickel solutions.

The Model 2200 monitors the bath's concentration, pH and cell temperature. When needed, it makes additions of nickel and hypophosphite replenishers and neutralizers to keep the solution within the proper operating range. It also keeps a record of the bath and its age, and the volume of chemicals used and remaining. These records can be used to track costs and profitability. In addition, its analyses can be transmitted to a printer by RS-232 data transfer.The controller also has audible, high and low level alarms to alert the operator to out-of -limit conditions.

The Model 2200 contains a custom designed, microprocessor to allow close control maximum flexibility, advanced record keeping. It is very user friendly. It prompts the operator to enter any required information through a menu selection process. Set points, alarm levels, bath volume, concentration and age, and sampling and addition times are all adjustable. The user can easily change them to account for changes in bath chemistry or volume. Automatic bath control can provide many benefits for the electroless nickel plater. It can increase production by maintaining the bath's operating parameters within close control and thus providing the maximum deposition rate. The bath's life is also extended by operating the solution at its optimum condition. This also helps provide consistent and quality deposits and reduces rejects. The better records produced by a controller also help to better manage the process and to better track costs.

 

PACKAGES

2200-B Nickel controller, sample pump, 50' Hi temperature sample hose, sample pick-up tube. Replenishment pumps are not included with this package.
2200-R Same as 2200-B with the addition of a Nickel/Hypo pump, 2 replenisher pickup tubes, and 200' of 1/2 " tubing.
2200-P Same as the 2200-R with the addition of pH pump 1 pH pickup tube, and 100' of 3/8" tubing.
2200-D Same as the 2200-P with the addition of a Data printer.

 

SPECIFICATIONS

Control Modes: Automatic: Closed Loop control with automatic addition of Ni replenisher, hypo, and pH adjuster.

Manual: A manual pump addition can be made with a displayed time.
Control Adjustments: One point and two point calibrations can be made for both the nickel metal analysis and pH.
A one point trim can be made to the cell temperature.
Control Setpoints: Tank volume, pump outputs, percentage addition, set point of addition, high Ni pH temperature, low Ni pH drum volumes, pH add point.
Control Limits: Nickel metal 4.0 g/l - 7.0 g/l
pH: 4.0 - 7.0 pH
Temperature: 0 - 100 Deg C
Alarm Modes: Nickel metal high, nickel metal low, pH high, pH low, cell temperature high, replenisher drum volume low.
Instrument Power: Controller - 110/220 Vac @ 15 Amps
Printer Output: Serial 1200 baud 50' max. cable length.
LCD Display: 4 x 20 backlite super twist LCD